Allen bradley softstarter smc-3 user manual

It features a builtin overload relay and a builtin scr bypass. In particular, this controller features soft start, soft stop, coasttorest, kickstart, and current limit start. Our smc3 soft starters are available with a current range from 3. Smc3 smc3 hold to testpush to reset button used to quickly test for fault conditions or reset the unit. Allen bradley smc 3 user manual allen bradley smc 3 user manual. They feature compact, true threephase control in a costeffective package. Bulletin 150 smart motor controllers smc plus 43 product selection open type controllers up to 480v ac up to 600v ac the minimum rating is. The smc3 is a compact, simple to use, solidstate motor controller designed to operate 3phase motors.

The controllers overload protection is programmable, providing the user with flexibility. Also, kits are now available to upgrade certain sizes of smc flex controller to smc 50 functionality. Smc 3, smc flex, and smc 50 smart motor controllers control mode overview allen bradley smc controllers have multiple control modes available to control standard 3 phase induction motors, depending upon the product selected. View and download allenbradley b series manual online. Consult your local rockwell automation sales office or allenbradley. Smc 150f5nbd, smc 150f108fad, smc 150f108fbd, smc 150f108fcd, smc 150f108fhd, smc 150f108nbd, smc 150f108nbr, smc 150f108ncd, etc. Allenbradley smc3 control unit manual pdf viewdownload. Smc3 low voltage soft starters allenbradley rockwell. Starting problem with soft starter cr4 discussion thread. Allen bradley does not assume responsibility or liability to include intellectual property liability for actual use based upon the examples shown in this publication. Figure 2 smc 50 soft starter with integral bypass approximate shipping cat. It is simple to use and its trimmed down design gives it a smaller footprint than that of similar models. Allen bradley softstarter smc 3 manual plc hardware. Allenbradley 150c201nbr allenbradley 150c201nbr smc3.

Trip reset is selectable to either automatic or manual mode. Hazardous location wizard, allen bradley 1 drives, allen bradley 2 condition monitoring 10. New allenbradley manual motor starter contactor 140mn0100 switzerland. The big eye opener for me was that the replacement power pole, one pole, for the new smc flex was more expensive than an entire 300hp soft starter chassis from several other sources. Allen bradley model 4088849001b1fx soft start controller repaired by erd with a 3 year warranty duration. Allen bradley 150c85nbr smc3 soft start motor drive 480vac d574459 product details. Find technical documentation to use our products effectively. Even the macbook air praised for how thin and light it is, still comes it at. Bulletin 150 smart motor controllers smc3 19 overviewmodes of operation your order must include 1 cat.

Utilizing these accessories, the smc delta and smc 3 become very modular and compatible with existing allen bradley product lines, allowing for a complete automation solution. For complete dimension drawings, see the user manual, publication 150um011, or consult your local rockwell automation sales office or allen bradley distributor. Smc 3 power connections smc 3 control terminals estop h4 h2 h1 h3 x1 x2 trans. This motor overload protection is accomplished electronically with the use of current transformers on each of the three phases. Iec isolation contactor configuration iec smc 3 control terminals h4 h2 h1 h3 x1 x2 trans. The allenbradley 150c16nbd is an smc3 solidstate smart motor controller with 5 modes of operation present. Allen bradley 150c37nbd series b motor controller 150c37nbd. Combination soft starter units are available globally in our. Mar 31, 2016 allen bradley model 4088849001b1fx soft start controller repaired by erd with a 3 year warranty duration. In particular, this controller features soft start, soft. For a full description of the control modes available for each product type, consult the appropriate product user manual. A start command will not be issued to the softstarter if a shorted scr condition is detected.

Rockwell automation1281 product lines product selection wizards 3. Rockwell automation new soft starter with internal bypass. Allenbradley smc controllers are microprocessor based soft starters that are. Surveillance 1 sensors and accessories 5 condition monitoring software 1 condition sensors, switches and controls 21. Rockwell automation expands family of smart motor controllers milwaukee the new allenbradley smc50 smart motor controller with internal bypass from rockwell automation brings greater operational control over motor starts and stops. Magnetic motor starters allen bradley cutlerhammer general the allen bradley heater tables below are two of the most heater element selection. Flexible and configurable auxiliary contacts easytomount sidemount auxiliary contact blocks make the smc delta and smc 3 suitable for a wide range of applications. Smc 3 make them ideal for almost any application, and with the available accessories, the functionality and application range is extended even. The shorted scr check is performed internally by the pcs, pf or pce softstarter as a prestart check. Bulletin 150 smart motor controllers smc2 the smc2 controller is a compact, multifunctional, versatile solid state controller used in starting standard threephase squirrelcage. Reduces downtime assists during setup easy and secure setup dip switches allow setting of the startstop profile, builtin overload, connection type, trip class and auxiliary contact characteristics.

The allen bradley controller smc 3 is a solidstate motor controller used to operate 3 phase motors. They include overload protection, integral bypass, and motor and system diagnostics. Allen bradley smc flex low voltage soft starter series. The smc3 is a compact, simple to use, solidstate motor controller designed to operate 3phase. Smcflex user manual literature library technical and.

We have new and used 150c85nbdby allenbradley in stock today. In the dads file, there is a variable called inc98. Smart motor controllers smc3, smc flex and smc50 soft. It features four modes of operation, including soft start, soft stop, current limit start, and kick start. As an extension of the soft starter family, the smc50 smart motor controller delivers greater functionality and efficiency across industries. The allen bradley 150c16nbd is an smc 3 solidstate smart motor controller with 5 modes of operation present. The unit with control wiring can be tested for fault conditions by using the push to. Users who would like to take advantage of the additional functionality of smc 50 soft starters, now have access to an internal bypass on that product line.

Soft starters were developed to overcome the drawbacks of direct on line dol and stardelta starting of single and three phase a. Specialized products for general usediscontinued products smc video library. Allen bradley is very secretive of their scr overload ratings and this has always made me suspicious. Allenbradley soft starter smc3 soft starter manual smc3 soft starter 3 phase motor soft starter with no nc and timer 100dny allenbradley smc3 smc3 allenbradley contactors 100c smc3 text. Chapter 1 catalog number identification the following is an explanation of the catalog numbering system for the bulletin 150 smc plus smart motor controller. Smc3, smc flex, and smc50 smart motor controllers literature. The smc3 controller incorporates, as standard, electronic motor overload protection. Shorted scr faults cannot be overridden through a parameter change for pf or dip switch change for pcspce. Installation and maintenance of solidstate control available from.

Allenbradley smc50 quick start manual pdf download. View and download allen bradley b series manual online. Use literature library to find a wide selection of publications that support rockwell automation, rockwell software, and allen bradley products, services, and solutions. Buy allen bradley 43 a soft starter smc3 series, ip2x, 22 kw, 200 460 v ac. Due to the size of the enclosure, the soft starter needed to fit in the space. Saf opal 100 hp soft starter ms6125c 125 amp pro ms6 solid start 100hp 125a ac. Important user information because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements. Specialized products for general usediscontinued productssmc video library. Allenbradley smc, smc3, and smcdelta are trademarks of rockwell automation.